Bone reconstruction after Removal of a Broken Implant
Last Updated: May 22, 2019
Implant failure can be caused by lack of integration, bone resorption, or prosthetic reasons. In the following case, a partially integrated overloaded implant was broken in its cervical part. The implant had to be removed and replaced by a new one. After removal of the implant and the granulomatous tissue a large bone deficiency was evident. An augmentation procedure was preformed by using Bond Apatite bone graft cement.
Surgical procedure:
- Minimally invasive envelop technique was performed by intrasulcular and mid- crestal incisions with minimal flap reflection to exposed the defect.
- After removal of the implant and the granulomatous tissue, Bond Apatite cement was injected and compacted into the site according to the bone cements application protocols .Thus, immediately after injecting the cement into the site a dry sterile gauze was place on the material with a firm finger pressure for 3 seconds buccally and occlusally, thereafter for additional few seconds a periosteal elevator was used to apply additional pressure in order to compact the cement properly in place.
- With bone cements, soft tissue manipulation is different and opposite of conventional grafting. The flap should be closed with tension and not tension free; primary closure is not mandatory since maximal closure is acceptable, which means that up to 3mm of graft exposure is completely fine but no more No membrane or PRF should be used in between the flap and the cement. Therefore no releasing incisions were done and flap closure was done by stretching and suturing in the sequence of MDM: first the mesial edge was sutured then the distal then middle and then in between them .
Healing was uneventful and after 3 months a new implant was placed and loaded after additional 3 months of healing with a fixed prosthesis.
2 Comments on Bone reconstruction after Removal of a Broken Implant
Dr.Amos Yahav
05/23/2019
Featured Products
Classic 50/50 Mix
Promotes osteoconduction
Provides structural integrity
Convenient Syringe!
50/50 Cortical/Cancellous
Available in 3 sizes.
Eliminate hassle of mixing particulate grafts
Sold in packs of 5 or packs of 10.
Proven safe, and clinically effective
Resorbable collagen membrane derived from purified porcine pericardium
Fast hydration and excellent tensile strength
Good adaptation to various defects
Excellent tear function and duration
100% allograft
Eliminates mixing hassle
Moldable after hydration
Dr. Gerald Rudick
05/23/2019