Osseo News Logo

The Original Dental Implant Community

Sign In

Bone reconstruction after Removal of a Broken Implant

Last Updated: May 22, 2019

Implant failure can be caused by lack of integration, bone resorption, or prosthetic reasons. In the following case, a partially integrated overloaded implant was broken in its cervical part. The implant had to be removed and replaced by a new one. After removal of the implant and the granulomatous tissue a large bone deficiency was evident. An augmentation procedure was preformed by using Bond Apatite bone graft cement.

Surgical procedure:

  • Minimally invasive envelop technique was performed by intrasulcular and mid- crestal incisions with minimal flap reflection to exposed the defect.
  • After removal of the implant and the granulomatous tissue, Bond Apatite cement was injected and compacted into the site according to the bone cements application protocols .Thus, immediately after injecting the cement into the site a dry sterile gauze was place on the material with a firm finger pressure for 3 seconds buccally and occlusally, thereafter for additional few seconds a periosteal elevator was used to apply additional pressure in order to compact the cement properly in place.
  • With bone cements, soft tissue manipulation is different and opposite of conventional grafting. The flap should be closed with tension and not tension free; primary closure is not mandatory since maximal closure is acceptable, which means that up to 3mm of graft exposure is completely fine but no more No membrane or PRF should be used in between the flap and the cement. Therefore no releasing incisions were done and flap closure was done by stretching and suturing in the sequence of MDM: first the mesial edge was sutured then the distal then middle and then in between them .

Healing was uneventful and after 3 months a new implant was placed and loaded after additional 3 months of healing with a fixed prosthesis.












2 Comments on Bone reconstruction after Removal of a Broken Implant

Dr. Gerald Rudick

05/23/2019

Very nice case...my question is why was the new replacement implant placed of such a small diameter, as there was a lot of space for a larger diameter implant, which would have stronger walls...…. the reason for the initial failure was due to excessive force on a weaker implant..

Dr.Amos Yahav

05/23/2019

the diameter here was 3.75 but definitely it can be also larger one

Featured Products

DALI Bone Mix

DALI Bone Mix

The highest quality tissue!

Classic

Classic 50/50 Mix

Promotes osteoconduction

Provides structural integrity

DALI Bone Syringe

DALI Bone Syringe

Prefilled Mineralized Cortico-Cancellous Bone in Syringe

New

Convenient Syringe!

50/50 Cortical/Cancellous

Available in 3 sizes.

Osteogen Plug

Osteogen Plug

Combines bone graft with a collagen plug.

Classic

Eliminate hassle of mixing particulate grafts

Sold in packs of 5 or packs of 10.

Proven safe, and clinically effective

OsseoSeal Flexible Membrane

OsseoSeal Flexible Membrane

Resorbable collagen membrane derived from purified porcine pericardium

Popular

Fast hydration and excellent tensile strength

Good adaptation to various defects

Excellent tear function and duration

DALI One Graft

DALI One Graft

One-Step grafting solution!

New

100% allograft

Eliminates mixing hassle

Moldable after hydration