Thoughts on slightly angulated implant?
Last Updated: Apr 20, 2015
I installed an implant in #30 site [mandibular right first molar; 46] using CBCT and a surgical guide stent, but still found end result to be angulated. While drilling the osteotomy, the drill was deflected to the mesial because of an area of dense sclerosing osteitis (this was know on pre-op preparation but unknown that it would force me mesial). After surgery and upon seeing the angulation I tried in the surgical guide again and noted that the centre of the healing abutment was about 2.5 mm distal to the ideal center of the final restoration. The orientation in the buccal- lingual dimension was right on. Because of this only 2-3 mm discrepancy from ideal, the implant was left as is and the patient was informed of a slight variation from ideal and it was explained that the presence of the dense bone island would make ideal placement more difficult. I realize the implant restoration will be bulky on the mesial aspect and not ideal but I believe the restoration to be functionally good and this slight deficit outweighs removing the implant and repositioning which would compromise otherwise healthy bone with a larger osteotomy. What are your thoughts ?
![]IMG_1649](https://osseonews.nyc3.cdn.digitaloceanspaces.com/wp-content/uploads/2015/04/IMG_1649-e1429496061837.jpg)
32 Comments on Thoughts on slightly angulated implant?
Kmk
04/20/2015
peterFairbairn
04/20/2015
Sb oms
04/20/2015
CRS
04/21/2015
kmk
04/22/2015
WBH
04/21/2015
DrT
04/21/2015
Dr. Gerald Rudick
04/21/2015
DrT
04/21/2015
kmk
04/22/2015
Raul Mena
04/21/2015
CRS
04/21/2015
kmk
04/22/2015
CRS
04/22/2015
Raul Mena
04/22/2015
CRS
04/24/2015
doctor john
04/21/2015
Carlos Boudet, DDS
04/21/2015
CRS
04/22/2015
Richard Hughes, DDS, FAAI
04/23/2015
CRS
04/24/2015
sergio
04/23/2015
DrT
04/23/2015
sergio
04/24/2015
Raul Mena
04/23/2015
CRS
04/24/2015
gordon
04/26/2015
CRS
04/26/2015
Raul Mena
04/26/2015
CRS
04/26/2015
john t
05/02/2015
Featured Products
Classic 50/50 Mix
Promotes osteoconduction
Provides structural integrity
Convenient Syringe!
50/50 Cortical/Cancellous
Available in 3 sizes.
Eliminate hassle of mixing particulate grafts
Sold in packs of 5 or packs of 10.
Proven safe, and clinically effective
Resorbable collagen membrane derived from purified porcine pericardium
Fast hydration and excellent tensile strength
Good adaptation to various defects
Excellent tear function and duration
100% allograft
Eliminates mixing hassle
Moldable after hydration
CRS
04/20/2015