implant special

What is the influence of the number of implants on the movement of overdentures?

Last Updated April 03, 2017
Reviewed By:  OsseoNews Team

The rotational movement of an implant overdenture (IOD) has a negative effect on the perceived masticatory ability of the denture wearer. However, the influence of implant number on the movement of implant overdentures has not been investigated. A study evaluated the denture movement of mandibular IODs anchored by different numbers of implants.
The conclusion:

Within the limitations of this in vitro study, the following conclusions were drawn: During mastication with the anterior teeth, the use of 2 implants for anchoring an IOD increased the rotation of the denture base more than the use of 1 or 3 implants. The horizontal movements of the IODs were small compared with the vertical movements. Denture movement under the occlusal force in the molar region was smaller than that in the anterior region.

Read the Full Abstract Here

1\. J Prosthet Dent. 2017 Mar;117(3):380-385. [Influence of implant number on the movement of mandibular implant overdentures](https://www.ncbi.nlm.nih.gov/pubmed/27677217) Oda K et al.

Bone Grafts

Wide selection of grafting materials for all clinical needs!

Membranes

Deliver predictable results with resorbable or non-resorbable options!

Surgical Kits

Specialized kits for Implant Surgery. Fixation Screws, PRF, and more!

Contact

20801 Biscayne Boulevard, Suite 403 Aventura, FL 33180

888-330-3964